• 一种应用于传感器模拟前端的电流反馈仪表放大器

    A current-feedback instrumentation amplifier applied to sensor analog front-ends

    • 针对传统斩波放大器引入额外纹波以及电流反馈仪表放大器(Current-Feedback Instrumentation Architecture, CFIA)输入共模电压与反馈共模电压失配等问题,设计了一种应用于传感器模拟前端的电流反馈仪表放大器。该设计在经典CFIA结构基础上,引入纹波抑制回路与共模均衡回路。纹波抑制回路有效抑制了斩波器引入的额外纹波,使输出纹波降低82 dB;共模均衡回路使输入共模电压与反馈共模电压在工作范围内保持相等,将相位裕度提升至70°以上。该CFIA采用TSMC 0.18 μm CMOS工艺实现。仿真结果表明:在1.8 V电源电压下,电路消耗电流为61 μA,输入参考噪声为22.97 nV/Hz1/2,失调电压为3.6 μV。该设计在保证低功耗的同时,实现了低噪声与低失调,适用于传感器模拟前端。

       

      Abstract: To address the issues of additional ripple introduced by traditional chopper amplifiers and the mismatch between input and feedback common-mode voltages in current-feedback instrumentation amplifiers (CFIA), a CFIA applied to sensor analog front-ends is designed. Based on the classic CFIA structure, a ripple reduction loop and a common-mode equalization loop are introduced. The ripple reduction loop effectively suppresses the additional ripple introduced by the chopper, reducing the output ripple by 82 dB. The common-mode equalization loop keeps the input common-mode voltage equal to the feedback common-mode voltage across the entire operating range, increasing the phase margin to over 70°. The CFIA is implemented in a TSMC 0.18 μm CMOS process. Simulation results show that under a 1.8 V supply voltage, the circuit consumes 61 μA of current, with an input-referred noise of 22.97 nV/Hz1/2 and an offset voltage of 3.6 μV. The design achieves low power consumption, low noise, and low offset, making it suitable for sensor analog front-ends.

       

    /

    返回文章